Electrical

Voltage Tolerance:

200-240V ±10%
380-480V ±10%
460-600V ±10%

Frequency Tolerance:

48-63 Hz

Input Phases:

Three-phase input provides full rating. Single-phase
operation provides 35% rated current.

Displacement Power Factor:

0.98 across entire speed range

Maximum Short Circuit Rating:

100,000 Amps Symmetrical

Actual Short Circuit Rating:

Determined by AIC Rating of installed fuse/circuit
breaker

Transistor Type:

Isolated Gate Bipolar (IGBT)

Control

Method:

Sinusoidal PWM, Volts/Hertz, and Sensorless Vector

Carrier Frequency

2-16 kHz, Drive rating based on 4 kHz.

Frequency Accuracy

Digital Input:
Analog Input:

Analog Output:

Within ±0.05% of set output frequency
Within 0.5% of maximum output frequency, 10-Bit
resolution
±2% of full scale, 10-Bit resolution

Speed Regulation

Open Loop with Slip Compensation:
With Encoder:

±1% of base speed across a 80:1 speed range
±0.3% of base speed across a 80:1 speed range
±0.05% of base speed across a 20:1 speed range

Output Frequency:

0-500 Hz (programmable)

Efficiency:

97.5% (typical)

Stop Modes:

Multiple programmable stop modes including - Ramp,
Coast, DC-Brake, and Ramp-to-Stop

Accel/Decel:

Four independently programmable accel and decel
times. Each time may be programmed from 0 - 600
seconds in 0.1 second increments.

Intermittent Overload:

150% Overload capability for up to 1 minute
200% Overload capability for up to 3 seconds

Electronic Motor Overload Protection

Provides class 10 motor overload protection according
to NEC article 430 and motor over-temperature
protection according to NEC article 430.126 (A) (2).
UL 508C File 29572.

Control Inputs

Digital:

Bandwidth:

10 Rad/Secs for open and closed loop

Quantity:

(2) Semi-programmable
(5) Programmable

Current:

6 mA

Type

Source Mode (SRC):
Sink Mode (SNK):

18-24V = ON, 0-6V = OFF
0-6V = ON, 18-24V = OFF

Analog:

Quantity:

(2) Isolated, –10 to 10V and 4-20mA

Specification

Resolution:
0 to 10V DC Analog:
4-20mA Analog:
External Pot:

10-bit
100k ohm input impedance
250 ohm input impedance
1-10k ohm, 2 Watt minimum

Encoder

Type:

Incremental, dual channel

Supply:

12V, 250 mA. 12V, 10 mA minimum inputs isolated
with differential transmitter, 250 kHz maximum.

Quadrature:

90°, ±27 degrees at 25 degrees C.

Duty Cycle:

50%, +10%

Requirements:

Encoders must be line driver type, quadrature (dual
channel) or pulse (single channel), 3.5-26V DC output,
single-ended or differential and capable of supplying a
minimum of 10 mA per channel. Allowable input is DC
up to a maximum frequency of 250 kHz. The encoder
I/O automatically scales to allow 5V, 12V and 24V DC
nominal voltages.