English-5

Category

Specification

Agency
Certification

Listed to UL508C and CAN/CSA-22.2

Certified to AS/NZS, 1997 Group 1, Class A

Marked for all applicable European Directives
EMC Directive (89/336)

EN 61800-3, EN 50081-1, EN 50082-2

Low Voltage Directive (73/23/EEC)

EN 50178, EN 60204

Certified to ISO 13849-1; Performance Level d (Safety
Category 3).
Meets Functional Safety (FS) when used with the
DriveGuard Safe-Off Option (Series B).

The drive is also designed to meet the appropriate portions of the following specifications:

NFPA 70 - US National Electrical Code
NEMA ICS 3.1 - Safety standards for Construction and Guide for Selection, Installation and

Operation of Adjustable Speed Drive Systems.

IEC 146 - International Electrical Code.

Protection

Bus Overvoltage Trip

200-240V AC Input:
380-460V AC Input:
460-600V AC Input:

405V DC bus (equivalent to 290V AC incoming line)
810V DC bus (equivalent to 575V AC incoming line)
1005V DC bus (equivalent to 711V AC incoming line)

Bus Undervoltage Trip

200-240V AC Input:
380-480V AC Input:
460-600V AC Input

P042 = 3 “High Voltage”:
P042 = 2 “Low Voltage”:

210V DC bus (equivalent to 150V AC incoming line)
390V DC bus (equivalent to 275V AC incoming line)

487V DC bus (equivalent to 344V AC incoming line)
390V DC bus (equivalent to 275V AC incoming line)

Power Ride-Thru:

100 milliseconds

Logic Control Ride-Thru:

0.5 seconds minimum, 2 seconds typical

Electronic Motor Overload Protection:

Provides class 10 motor overload protection according
to NEC article 430 and motor over-temperature
protection according to NEC article 430.126 (A) (2).
UL 508C File 29572.

Overcurrent:

200% hardware limit, 300% instantaneous fault

Ground Fault Trip:

Phase-to-ground on drive output

Short Circuit Trip:

Phase-to-phase on drive output

Environment

Altitude:

1000 m (3300 ft) max. without derating. Above 1000 m
(3300 ft) derate 3% for every 305 m (1000 ft).

Maximum Surrounding Air Temperature
without derating:

IP20, Open Type:
IP30, NEMA Type 1, UL Type 1:
Flange and Plate Mount:

–10 to 50° C (14 to 122° F)
–10 to 40° C (14 to 104° F)
Heatsink:

–10 to 40° C (14 to 104° F)

Drive:

–10 to 50° C (14 to 122° F)

Cooling Method

Convection:
Fan:

0.4 kW (0.5 HP) drives and all Flange and Plate drives
All other drive ratings

Storage Temperature:

–40 to 85 degrees C (–40 to 185 degrees F)

Atmosphere:

Important: Drive must not be installed in an area
where the ambient atmosphere contains volatile or
corrosive gas, vapors or dust. If the drive is not going
to be installed for a period of time, it must be stored in
an area where it will not be exposed to a corrosive
atmosphere.

Relative Humidity:

0 to 95% non-condensing

Shock (operating):

15G peak for 11ms duration (

±

1.0 ms)

Vibration (operating):

1G peak, 5 to 2000 Hz

UL

®

C

US

TUV

Rheinland

Product Safety

.

.

Production inspected

W

E

C

TUV

Rheinland

.

.

Functional

Safety

Bauart geprüft

Type approved

EN 50178

Advertising