PowerFlex 40 Standard Configured Drive Standard Features and Options

Auto/Manual Selector Switch (Position 16+, Code S4)

This 800F door mounted operator device is factory installed and provides an
Auto/Manual selector switch.

The Auto/Manual selector switch determines the source of the actual drive speed
reference. Using 2-wire control in Auto mode, speed source is parameter A071
[Preset Freq 1]. In Manual mode, the speed source is parameter A072 [Preset
Freq 2].

If the door mounted speed potentiometer (Option S18) is supplied and it is
intended to be the speed reference in Manual mode, set parameter P052 [Digital
In2 Sel] to option 13 “10V In Ctrl.” Refer to the table below and the PowerFlex
40 User Manual, publication

22B-UM001

, for other options.

Auto/Manual Selector Switch (Code S4)

Component Specifications

This option is not compatible with Codes R3, R5, S1, S20, S21 or S22.

Speed Reference

Parameter Settings

Manual Mode

Auto Mode

P038 [Speed Reference]

A051 [Digital In1 Sel]

A052 [Digital In2 Sel]

Preset Speed

Preset Speed

4 “Preset Freq”

4 “Preset Freq”

4 “Preset Freq”

Analog Input (0-10V)

4 “Preset Freq”

13 “10V In Ctrl”

4 “Preset Freq”

Analog Input (4-20mA)

4 “Preset Freq”

14 “20mA In Ctrl”

4 “Preset Freq”

Communication Port

(1)

4 “Preset Freq”

6 “Comm Port”

4 “Preset Freq”

Speed Pot (Door)

Preset Speed

4 “Preset Freq”

4 “Preset Freq”

13 “10V In Ctrl”

Analog Input (4-20mA)

4 “Preset Freq”

14 “20mA In Ctrl”

13 “10V In Ctrl”

Communication Port

(1)

4 “Preset Freq”

6 “Comm Port”

13 “10V In Ctrl”

HIM (Door)

Preset Speed

4 “Preset Freq”

4 “Preset Freq”

6 “Comm Port”

Analog Input (0-10V)

4 “Preset Freq”

13 “10V In Ctrl”

6 “Comm Port”

Analog Input (4-20mA)

4 “Preset Freq”

14 “20mA In Ctrl”

6 “Comm Port”

(1) Communication port will have both logic and reference control.

Bulletin 800F Devices

IEC style, Internationally rated
Meet IP65/IP66 and NEMA/UL Type 4/4X/13
UL Listed, CSA Certified
10 amp contacts
Screw terminals, 0.3…3.5 mm

2

(22…12 AWG) maximum

Auto/Manual
Selector Switch

2 position, Maintained
1 N.C. contact

Legend Plate

30 x 50 mm, Black with white lettering

Wiring

0.8 mm

2

(18 AWG), Blue

Schematics

Figure 6 on page 33

,

Figure 7 on page 34

,

Figure 8 on page 35