Component specifications – Rockwell Automation 22B PowerFlex 40 Configured AC Drives User Manual

Page 19

Advertising
background image

Rockwell Automation Publication 23B-IN001K-EN-P - September 2013

19

PowerFlex 40 Standard Configured Drive Standard Features and Options

Chapter 1

Start and Stop Push Buttons (Position 16+, Code S7)

This option provides factory installed 800F Start and Stop push buttons.

In all cases, the Stop input to the drive must be present before the drive will start.
Using 3-wire control, speed source is parameter A070 [Preset Freq 0]. The Stop
push button may also be used as a fault reset.

Component Specifications

This option is not compatible with Codes R3, R5, S1, S20, S21, S22 or S23.

Forward/Reverse Selector Switch (Position 16+, Code S8)

This 800F door mounted operator device is factory installed and provides a
Forward/Reverse selector switch.

When configured for 2-wire control, the drive will start when the selector switch
is set to Forward. When the selector switch is set to Reverse, the drive will run in
reverse. If the selector switch is operated while the drive is running, a change of
direction command will occur. If the drive is stopped and the selector switch is
operated, a change of direction command will occur. The speed source is
parameter P070 [Preset Freq 0].

When configured for 3-wire control (Code S7 with S8), the selector switch only
changes direction. The drive is started and stopped via the Start and Stop push
buttons (Code S7).

Component Specifications

This option is not compatible with Codes R3, R5, S20 or S21.

Bulletin 800F Devices

IEC style, Internationally rated
Meet IP65/IP66 and NEMA/UL Type 4/4X/13
UL Listed, CSA Certified
10 amp contacts
Screw terminals, 0.3…3.5 mm

2

(22…12 AWG) maximum

Start Push Button

Flush head, Green, 1 N.O. contact

Stop Push Button

Extended head, Red, 1 N.C. contact

Legend Plate

30 x 50 mm, Black with white lettering

Wiring

0.8 mm

2

(18 AWG), Blue

Schematics

Figure 7 on page 34

,

Figure 9 on page 36

,

Figure 10 on page 37

Bulletin 800F Devices

IEC style, Internationally rated
Meet IP65/IP66 and NEMA/UL Type 4/4X/13
UL Listed, CSA Certified
10 amp contacts
Screw terminals, 0.3…3.5 mm

2

(22…12 AWG) maximum

Forward/Reverse
Selector Switch

2-Wire: 2 position, Maintained, 1 N.O. & 1 N.C. contacts
3-Wire: 2 position, Maintained, 1 N.C. contact

Legend Plate

30 x 50 mm, Black with white lettering

Wiring

0.8 mm

2

(18 AWG), Blue

Schematics

2-Wire Control:

Figure 5 on page 32

,

Figure 8 on page 35

,

Figure 11 on page 38

3-Wire Control:

Figure 10 on page 37

Advertising
This manual is related to the following products: