14 High Frequency 13.56 MHz RFID EtherNet/IP Interface Block

Drawing Number

10000181820 Ver. 01 - November 2012

Network
status LED

Off

The device is not initialized or the module does not
have an IP address.

Flashing green

The device has no CIP connections.
The device has an IP address, but no CIP connections
are established.

Green

The device is online, has an IP address, and CIP
connections are established.

Flashing red

One or more connections have timed out.

Red

The module has detected that its IP address is
already in use.

Link1 and
Link2 LEDs

Off

No link established.

Green

Link established on indicated port at 100 Mbps.

Flashing green

Link activity present on indicated port at 100 Mbps.

Yellow

Link established on indicated port at 10 Mbps.

Flashing yellow

Link activity present on indicated port at 10 Mbps.

Auxiliary
status

Off

No power

Green

Communicating

Transceiver
Module
Status LED

Green

Power ON

No illumination

No power

Transceiver
Read/Write
LED

Green

Normal operation

Flashing green (short interval)

Communicating

Flashing amber (short interval)

Sensing tag

Flashing red (long interval)

Communication error

Flashing green (long interval)

No tag

I/O LED

Off

I/O off

Yellow

I/O on

IMPORTANT

The Module Status LED indicator will flash red and green for a maximum
30 s while the module completes its POST (Power-On Self Test).

Indicator Status for Modules

Status

Description

Advertising