16 High Frequency 13.56 MHz RFID EtherNet/IP Interface Block
Drawing Number
10000181820 Ver. 01 - November 2012
Leakage current, off-state output,
max.
50
µA
Surge current per output, max.
1.2 A for 10 ms, repeatable every 2 s
Isolation voltage
50V (continuous), basic insulation type, outputs and output power
to network
No isolation between individual outputs or between outputs and
output power or between network channels
Type tested at 707V DC for 60 s
EtherNet/IP Interface Block RFID – 56RF-IN-IPS12 and 56RF-IN-IPD22
Attributes
Value
Voltage
24V DC (-20…+10%)
Output current per RFID port, max.
100 mA @ 24V DC
EtherNet/IP Interface Block Output – 56RF-IN-IPS12 and 56RF-IN-IPD22
Attributes
Value