18 High Frequency 13.56 MHz RFID EtherNet/IP Interface Block

Drawing Number

10000181820 Ver. 01 - November 2012

Environmental Specifications

Attribute

Value

Temperature, operating

IEC60068-2-1/2, Test Ad/Bd
Cold: -20 °C (-4 °F)
Dry Heat: 60 °C (140 °F)
Gradient: 1 °C (33.8 °F)/min
Duration: 33.6 hr with insulation tests

Temperature, storage

IEC60068-2-1/2, Test Ad/Bd
Cold: -40 °C (-40 °F)
Dry Heat: 85 °C (185 °F)
Gradient: 1 °C (33.8°F)/min
Duration: 33.6 hr with insulation tests

Relative humidity

IEC60068-2-30, Test Db
Temperature Cycle Range: 20-60-20 °C (68-140-68 °F)
Humidity Cycle Range: 80…95% non-condensing

Vibration

IEC60068-2-6
Frequency Range: 10…500 Hz
Acceleration: 5 g
Displacement: 0.030 in. (p-p)
Duration: One octave per minute sweep rate
No. of sweeps: 10
Vertical mounting

Shock, operating

IEC60068-2-27
Acceleration:30 g, 11 ms
Vertical mounting

Shock, non-operating

IEC60068-2-32, Test Ea
Acceleration: 50g, 11 ms
Vertical mounting

Emissions

IEC61000-6-4, (CISPR11)
Class A

ESD susceptibility
(Performance Criteria B)

IEC61000-4-2
Indirect (Coupling Plate): +/-6 kV contact discharge
Direct (to “Points of Initial Contact”): +/-6 kV contact discharge; +/-8 kV
air discharge

Radiated RF immunity
(Performance Criteria A)

IEC61000-4-3, ENV50204
80…1000 MHz: 10V/m, with 1kHz sine wave 80% AM
1…2 GHz: 10V/m, with 1 kHz sine wave 80% AM
900 MHz Pulse: 10V/m, with 200 Hz 50% pulse 100% AM
1.89 GHz Pulse: 10V/m with 200 Hz 50% pulse 100% AM
2…2.7 GHz: 1V/m, with 1 KHz sine wave 80% AM