Compliance, Environmental specifications – Rockwell Automation 56RF High Frequency 13.56 MHz RFID EtherNet/IP Interface Block User Manual

Page 19

Advertising
background image

High Frequency 13.56 MHz RFID EtherNet/IP Interface Block 19

Drawing Number

10000181820 Ver. 01 - November 2012

EFT/B immunity
(Performance Criteria B)

IEC61000-4-4
DLR Ports: +/-3 kV clamp inject at 5 kHz for 5 min
Module and Output Power: +/-3 kV clamp inject at 5 kHz for 5 min
Digital I/O: +/-3 kV clamp inject at 5 kHz for 5 min
Analog I/O: +/-3 kV clamp inject at 5 kHz for 5 min
Earth Ground: +/-3 kV clamp inject at 5 kHz for 5 min

Surge immunity
(Performance Criteria B)

IEC61000-4-5
DLR Ports: +/-2 kV common mode @ 2 ohms
Module and Output Power: +/-2 kV common mode @ 12 ohms; +/-2 kV
differential mode @ 2 ohms
Shielded Digital I/O: +/-2 kV common mode @ 2 ohms
Shielded Analog I/O: +/-2 kV common mode @ 2 ohms

Conducted radiated
immunity
(Performance Criteria A)

DLR Ports, Module Power, Output Power, Digital I/O, and Analog I/O
150 kHz…80 MHz, CDN inject
10V, with 1 kHz sine wave 80% AM

Compliance

Compliance (when

product is marked)

(1)

(1)

See the Product Certification link at

http://www.ab.com

for Declarations of Conformity, Certificates,

and other certification details.

Value

CE

European Union 2004/108/EC EMC Directive, compliant with:

EN 61326-1; Meas./Control/Lab., Industrial Requirements

EN 61000-6-2; Industrial Immunity

EN 61000-6-4; Industrial Emissions

EN 61131-2; Programmable Controllers (Clause 8, Zone A & B)

EtherNet/IP

ODVA conformance tested to Ethernet/IP specifications.

Environmental Specifications