General specifications – Rockwell Automation 56RF High Frequency 13.56 MHz RFID EtherNet/IP Interface Block User Manual

Page 17

Advertising
background image

High Frequency 13.56 MHz RFID EtherNet/IP Interface Block 17

Drawing Number

10000181820 Ver. 01 - November 2012

General Specifications

Attributes

Value

Voltage, auxiliary power

(1)

(1)

Intended to be powered by a limited voltage, limited current supply.

24V DC (-20…+10%)

Auxiliary current per module, max.

(2)

(2)

A Listed or Recognized 4 A fuse shall be installed on the line side of the device.

4 A

Output current per RFID transceiver port, max.

100 mA @ 24V DC

Current for output device power per I/O port,
max.

0.5 A @ 30V

Current for input device power per I/O port,
max.

5 mA @ 30V

Communication rate

EtherNet/IP

10/100 Mbps

Full or half-duplex

100 meter per segment

LED indicators

Module Status - red/green

Network Status - red/green

Link Status - green/yellow

Auxiliary Power - green

I/O LED - yellow

Dimensions (HxWxD), approx.

179x37x43.25 mm (7.05x1.46x1.7 in.)

Weight, approx.

0.2 kg (0.45 lb)

Enclosure type rating

IP67 and IP69K

Wiring category

(3)

(3)

Use this Conductor Category information for planning conductor routing. Refer to publication

1770-4.1

,

Industrial Automation Wiring and Grounding Guidelines.

1 - on signal ports
1 - on power ports
1 - on communications ports

Advertising