Appendix B Option Module Parameters
18
[DHCP]
Enables/disables the Dynamic Host Configuration
Protocol server for setting the IP address, subnet
mask, and gateway address of the option module.
Default:
0 = Disabled
Values:
0 = Disabled
1 = Enabled
Type:
Read/Write
Reset Required: Yes
19
[Web Enable]
Enables/disables the option module web pages.
Default:
0 = Disabled
Values:
0 = Disabled
1 = Enabled
Type:
Read/Write
Reset Required: Yes
20
[Web Features]
Enables/disables the web-configurable e-mail
notification feature.
Type:
Read/Write
Reset Required: No
Parameter
No.
Name and Description
Details
Bit
Definition
No
t U
se
d
No
t U
se
d
No
t U
se
d
No
t U
se
d
No
t U
se
d
No
t U
se
d
No
t U
se
d
E-mail Cfg
Default
x
x
x
x
x
x
x
1
Bit
7
6
5
4
3
2
1
0
0 = Disabled
1 = Enabled
x = Reserved