5-6

Configuring a Scanner to Communicate with the Encoder

Figure 5.4

Edit I/O Parameters Dialog Box - COS

9. Select the type(s) of data exchange (Polled, Change of State,

and/or Cyclic). In our example, we selected Change of State.

10. Type the number of bytes that will be required for your I/O in the

Rx Size and Tx Size. See Assembly Data Format, page B-4, for
data sizes.

11. Set the scan rate:

Click Help for more information.

12. When using COS in high speed and/or high resolution

applications, it may be necessary to limit how often the device
will report to the master in order to lessen network traffic. To do
so requires either setting the hysteresis to over 10% of the
‘RESOLUTION PER REVOLUTION’ value or increasing the
‘Inhibit Time’. To increase the inhibit time to 10ms, click on the
Advanced... button under ‘Change of State/Cyclic.’ Adjust the
Inhibit Time and click OK.

Data

Exchange

Rate to set

Polled

Polled Rate

Change of
State

Heartbeat
Rate

Cyclic

Send Rate

Advertising
This manual is related to the following products: