Configuring a Scanner to Communicate with the Encoder

5-7

Figure 5.5

Inhibit time

13. In the Edit I/O Parameters box, click OK. If you changed any

settings, a Scanner Applet appears and asks if it is OK to unmap
the I/O. Click Yes to continue. The Edit I/O Parameters dialog
box closes and then the Scanner Module dialog box (Figure 5.3)
reappears. You will map the I/O in the next section in this chapter.

Mapping the Product’s Data in
the Scanner

Data from I/O messages must be mapped in the scanner. This
mapping determines where a ladder logic program can find data
transmitted on the network.

Mapping the Input I/O

In the Scanner Module dialog box, click the Input tab. (If you need to
display this dialog box, right-click the scanner in the configuration
view. See Figure 5.1.). Below, the input pages for Change of State,
Polled and Strobed are shown.

Figure 5.6

Scanner Module Dialog Box, Input Page - COS

Advertising