Rockwell Automation Publication 1441-UM004A-EN-P - May 2011

31

Balancing Extension Module Chapter 2

5.

When the speed, vibration, and phase values are stable, press Enter.

The trial weight measurement is complete and the results are stored in the
Vibration Summary Table.

A message appears asking if the trial weight is still attached:

Press F2 (Yes) if the weight is still attached to the rotor.
Press F3 (No) if the weight has been removed from the rotor.

6.

Shut down the machine.

TIP

It is good practice to remove the trial weight.

TIP

Anytime during the initial run, you can do the following:

Press F4 (Esc) to exit the balancing program.

Press 0 (Shift) and F1 (Go to) simultaneously to go back to a
previous step in the balance run.

See

Move Around in a Balance Run on page 60

for details.

Press F2 (Summary) to display the results in the Vibration
Summary Table.

See

Review Balancing Measurements on page 63

for details.