Balancing Extension Module Chapter 2
The data collector automatically measures the speed, vibration, and phase.
The values are constantly updated on the screen.
4.
When the speed, vibration, and phase values are stable, press Enter.
The residual measurement is complete.
5.
Do one of the following.
• Press F2 (Yes) to trim the residual. The data collector calculates the trim
correction weights and displays the following screen.
You can split the trim weight and modify the radius.
• Press F3 (No) if you do not want to trim the residual.
The Vibration Summary Table appears.
Split the Correction Weight on page 42
for details.
6.
Shut down the machine and attach the trim weight(s) whose weight, angle,
and radius are indicated on the screen.
7.
Start the machine and let it reach operating speed.
8.
Press Enter.
TIP
The green status indicator illuminates when the
measurement is complete.
• Amber is waiting for data acquisition
• Red ICP or overrange detection fault.
IMPORTANT
Do not remove the original correction weight.