Rockwell Automation 1441-DYN25-MBAL Balancing Extension Module for the Dynamix 2500 User Manual

Page 51

Advertising
background image

Rockwell Automation Publication 1441-UM004A-EN-P - May 2011

51

Balancing Extension Module Chapter 2

Two-plane Balancing with One Transducer

Follow these steps to begin the two-plane balancing procedure with one
transducer.

1.

Start the machine and bring it up to its steady running speed.

2.

At the Balance Setup screen, press Enter to begin taking reference run data.

You are prompted to verify the transducer is attached to the bearing
nearest Plane.

3.

Verify the transducer on Plane 1 and press OK.

The data collector initiates the initial run measurements for Plane 1. The
Initial Run – Plane 1 screen displays the measurement results.

If two transducers are used for the balancing, both planes appear
simultaneously. You may skip to the next section.

4.

Press Enter to proceed.

Advertising