Chapter 5 – Programming
5-40
Faults Group (cont.)
[Cur Lim Trip En]
Parameter # 82
Factory Default ‘‘Default Run”
[Cur Lim Trip En]
Parameter Type Read & Write
This setting determines whether or not exceeding the
se
rren L
use
s
urre
Units None
Setting ‘‘Trip @ I Lim”
A Diagnostic Current Limit Fault is generated
setting in [Current Limit] will cause a Diagnostic Current
Limit Fault (Fault F36).
‘‘Default Run”
No fault generated
[Line Loss Fault]
Parameter # 40
Factory Default ‘‘F03 Enable”
[Line Loss Fault]
Parameter Type Read & Write
This setting determines whether a 15% drop in DC Bus
voltage will have no effect on operation or cause a ‘‘Power
ss
u
u
)
Units None
Setting ‘‘UVolt Run”
‘‘Power Loss Fault” Disabled
Loss Fault” (fault F03).
IMPORTANT
:
The “Line Loss” alarm bit will be set when
this condition exists regardless of the parameter setting.
‘‘FO3 Enable”
Drive Trips at 85% of nominal bus voltage.