Rockwell Automation 1305 AC Drive, Series A and B, Firmware 4.xx-5.xx User Manual
Page 36

Chapter 2 – Installation/Wiring
2-20
Figure 2.9 Terminal Block (TB2) Designations
[Input Mode] = “3 Wire/MOP”
Figure 2.10 Terminal Block (TB2) Designations – Two Wire
Control Operation [Input Mode] = “Run F/R MOP”
Jumper
Run
Re-
verse
Remote
Pot
1
2
4
5
6
7
8
9
10
0-10 Volts
Source
Wiper or 0-10VDC Input
Common
4-20mA Input
0-10V Output
Common
Stop
Output
#1
Start
Momentary input
Maintained input
Wires must be
shielded
➀
3
Common
Reverse
Jog
Common
MOP Increment
MOP Decrement
(Sink)
11
12
13
14
15
16
17
18
19
20
Enable
Frequency Source
Output #2
Remote
Pot
Run
For-
ward
1
2
4
5
6
7
8
9
10
0-10 Volts
Source
Wiper or 0-10VDC Input
Common
4-20mA Input
0-10V Output
Common
Stop
Output
#1
➁
Start
3
Common
Reverse
Jog
Common
MOP Increment
MOP Decrement
(Sink)
11
12
13
14
15
16
17
18
19
20
Enable
Frequency Source
Output #2
➄
➀➃
24VDC Source
(User Supplied)
Customer Side
Customer Side
24VDC Source
(User Supplied)
See Table 2.F and notes on page 2-21.
Jumper
Typical for Shield Connections
Shield
Common
(Connect at drive TB2 only)
➂
➂
➂
➂
➂
➂
➂
➂
➂
➂
➂
➂
➂
➂
➂
➂
➀
➀➃
➅
➅
➅
➅
➅
➅