Appendix b – Rockwell Automation 1305 AC Drive, Series A and B, Firmware 4.xx-5.xx User Manual
Page 154

Appendix B –
Serial Communications
B-6
Table B.4 Parameter Grouping/User Settings (cont.)
Group
Parameter Name
Parameter #
Display
Units
Drive Units
Scale Factor ➁
Min
Max
Factory Setting
User‘s
Setting
Input Mode
21
Text ➀
1
––
––
Three Wire
Freq Select 1
5
Text ➀
1
––
––
Adapter 1
Accel Time 1
7
Seconds
10
0.0
3600.0
10.0
Decel Time 1
8
Seconds
10
0.0
3600.0
10.0
p
Base Frequency
17
Hz
1
40
400
60
Up
Base Voltage
18
Volts
1
25% of DRV
Drive Rated Volts
Drive Rated Volts
S
et U
Maximum Voltage
20
Volts
1
25% of DRV
Drive Rated Volts
Drive Rated Volts
S
e
Minimum Freq
16
Hz
1
0
120
0
Maximum Freq
19
Hz
1
40
400
60
Stop Select
10
Text ➀
1
––
––
Ramp
Current Limit
36
%
1
20% of DRC
150% of Drive Rated Current (DRC)
150% of DRC
Overload Mode
37
Text ➀
1
––
––
No Derating
Overload Current
38
Amps
100 = DRC
20% of DRC
115% of Drive Rated Current (DRC)
115% of DRC
Sec Curr Limit
141
%
1
0
150% of Drive Rated Current (DRC)
0
➀ Refer to Table B.5 on pages B-13, B-14 and B-15 for the numerical equivalent of the text descriptions. ➁ Refer to page B-2.