14

Publication 1769-UM020A-EN-P - December 2009

Chapter 2 Installation and Wiring

Hazardous Location Considerations

This equipment is suitable for use in Class I, Division 2, Groups A, B,
C, D or nonhazardous locations only. The following attention
statement applies to use in hazardous locations.

Preventing Electrostatic Discharge

ATTENTION

EXPLOSION HAZARD

Substitution of components may impair suitability for Class I,
Division 2.

Do not replace components or disconnect equipment unless
power has been switched off or the area is known to be
nonhazardous.

Do not connect or disconnect components unless power has
been switched off or the area is known to be nonhazardous.

This product must be installed in an enclosure.

All wiring must comply with N.E.C. article 501-4(b).

ATTENTION

Electrostatic discharge can damage integrated circuits or
semiconductors if you touch analog I/O module bus-connector pins
or the terminal block on the module. Follow these guidelines when
you handle the module:

Touch a grounded object to discharge static potential.

Wear an approved wrist-strap grounding device.

Do not touch the bus connector or connector pins.

Do not touch circuit components inside the module.

Use a static-safe work station, if available.

Keep the module in its static-shield box, when it is not in use.