18 SSI Servo Module

Publication

1756-IN595A-EN-P - March 2004

The table below provides an explanation of the DRIVE indicator.

If the DRIVE
LED displays:

The module status is:

Take this action:

Off

One of the following:

• The axis is not

used.

• The axis is a

position- only axis
type.

• None, if the axis is not used or

is a position- only type.

• Otherwise, make sure the

module is configured, an axis
tag has been associated with
the module, and the axis type is
servo.

Flashing green
light

The axis drive is in the
normal disabled state.

None. The servo axis state can be
changed by executing motion
instructions.

Steady green
light

The axis drive is in the
normal enabled state.

None. The servo axis state can be
changed by executing motion
instructions.

Advertising