background image

SmartGuard 600 Controllers 23

Publication 1752-IN001C-EN-P - January 2009

Refer to the SmartGuard 600 Controller User Manual, publication

1752-UM001

, for

more information on recovering from I/O errors.

EtherNet/IP Communication (COMM E) Status Indicator Descriptions

If the EtherNet/IP
Communication
(COMM E) status
indicator is

It means

Take this action

Green, on

The controller is communicating on
the Ethernet network.

No action required.

Off

The controller is not communicating
on the Ethernet network.

Ethernet Network Speed (100) Status Indicator Descriptions

If the Ethernet
Network Speed (100)
status indicator is

It means

Take this action

Yellow, on

The communication rate is 100 Mbps. No action required.

Off

(1)

(1)

If this indicator is Off along with the Network Speed (10) indicator, check your Ethernet connection.

The communication rate is 10 Mbps.

Check that the Network Speed (10) indicator
is on.

Ethernet Network Speed (10) Status Indicator Descriptions

If the Ethernet
Network Speed (10)
status indicator is

It means

Take this action

Yellow, on

The communication rate is 10 Mbps.

No action required.

Off

(1)

(1)

If this indicator is Off along with the Network Speed (100) indicator, check your Ethernet connection.

The communication rate is 100 Mbps. Check that the Network Speed (100) indicator

is on.

ATTENTION

Status indicators are not reliable indicators for safety functions. They should be used
only for general diagnostics during commissioning and troubleshooting. Do not use
status indicators as operational indicators.