Rockwell Automation 1791DS-IBxxxx Guard I/O DeviceNet Safety Modules User Manual

Page 18

Advertising
background image

18

Rockwell Automation Publication 1791DS-UM001J-EN-P - May 2013

Chapter 1

About the Modules

The following is a list of features common to Guard I/O modules:

CIP-safety and DeviceNet protocol conformance
Safety inputs

Safety devices, such as emergency stop push buttons, gate switches, and

safety light curtains, can be connected.

Dual-channel mode evaluates consistency between two input signals

(channels), which allows use of the module for Safety Category 3 and 4.

The time of a logical discrepancy between two channels can be

monitored using a discrepancy time setting.

An external wiring short-circuit check is possible when inputs are wired

in combination with test outputs. The module must be wired in
combination with test outputs when this function is used.

Independently adjustable on and off delay is available per channel.

Test outputs

Separate test outputs are provided for short circuit detection of a safety

input (or inputs).

Power (24V) can be supplied to devices, such as safety sensors.
Test outputs can be configured as standard outputs.
All Guard I/O modules have numerous test outputs, of which some can

be used for broken wire detection of a muting lamp.

Safety outputs

Solid state outputs

• Dual-channel mode evaluates consistency between two output signals
(channels).
• Safety outputs can be pulse tested to detect field wiring shorts to 24V
DC.
• All 1791DS-IB8XOBV4 modules’ safety outputs use pulse testing to
detect a short to 24V DC on the safety source output (P), and a short to
0V DC on the safety sink output (M).

Relay Outputs

• Dual-channel mode evaluates consistency between two output signals
(channels).
• Up to 2 A is provided per output point.
• Safety relays can be replaced.

I/O status data - In addition to I/O data, the module includes status data

for monitoring I/O circuits.

Security - The configuration information of the module can be protected

by a password.

Removable I/O connectors - I/O connectors support mechanical keying.

Advertising