Rockwell Automation Publication 1732E-UM003B-EN-E - March 2014

105

Appendix

C

Data Tables

Communicate with Your
Module

Read this section for information about how to communicate with your module.

I/O messages are sent to (consumed) and received from (produced) the
ArmorBlock I/O modules. These messages are mapped into the processor or
scanner memory. The following table lists the assembly instances and connection
points for the 1732E EtherNet/IP ArmorBlock Sequence of Events Input and
Scheduled Sourcing Output Modules.

Connection Points

In the following tables, Input pertains to the produced data from the module to
the controller, and Output refers to consumed data by the module from the
controller.

Catalog Number

Connection Format

Timestamp

Module-Defined
Data Type

Assembly Instance /
Connection Point
(decimal)

1732E-IB8M8SOER

Data (default)

Per Point (default)

Configuration

111

Input

157

Output

159

Data

First In First Out

Configuration

111

Input

158

Output

159

Data

None

Configuration

111

Input

104

Output

191

Listen Only

None

Configuration

189

Input

104

Output

191

1732E-OB8M8SR

(1)

Per Point

Configuration

171

Input

177

Output

174

None

Configuration

171

Input

191

Output

34

(1) There is no Listen Only connection for the 1732E-OB8M8SR because consumed assembly data is dependent on data in the produced assembly.