Load Initial Configuration Values

Chapter 7

7-29

Table 7.A presents unselected valve setpoints you may wish to use,
depending on your machines valve types and the desired profile action.

Table 7.A

Unselected Valve Setpoints

If the unselected

valve controls:

And the unselected

valve configuration is:

And during the

profile the valve is:

And you require

during the profile:

Then Enter:

Pressure

UniĆdirectional

Direct acting

Maximum Pressure 9999

Pressure

UniĆdirectional

Direct acting

Medium Pressure

7500 to

5000

Pressure

UniĆdirectional

Direct acting

Low Pressure

5000 to

2500

Pressure

UniĆdirectional

Direct acting

Minimum Pressure 0

Pressure

UniĆdirectional

Reverse acting

Maximum Pressure 0

Pressure

UniĆdirectional

Reverse acting

Medium Pressure

2500 to

5000

Pressure

UniĆdirectional

Reverse acting

Low Pressure

5000 to

7500

Pressure

UniĆdirectional

Reverse acting

Minimum Pressure 9999

Flow

UniĆdirectional

Direct acting

Maximum Flow

9999

Flow

UniĆdirectional

Direct acting

Medium Flow

7500 to

5000

Flow

UniĆdirectional

Direct acting

Low Flow

5000 to

2500

Flow

UniĆdirectional

Direct acting

Minimum Flow

0

Flow

UniĆdirectional

Reverse acting

Maximum Flow

0

Flow

UniĆdirectional

Reverse acting

Medium Flow

2500 to

5000

Flow

UniĆdirectional

Reverse acting

Low Flow

5000 to

7500

Flow

UniĆdirectional

Reverse acting

Minimum Flow

9999

Flow

BiĆdirectional

Direct acting

Maximum Flow

9999

Flow

BiĆdirectional

Direct acting

Medium Flow

8750 to

7500

Flow

BiĆdirectional

Direct acting

Low Flow

7500 to

6250

Flow

BiĆdirectional

Direct acting

Minimum Flow

5000

Flow

BiĆdirectional

Reverse acting

Maximum Flow

0

Flow

BiĆdirectional

Reverse acting

Medium Flow

1250 to

2500

Flow

BiĆdirectional

Reverse acting

Low Flow

2500 to

3750

Flow

BiĆdirectional

Reverse acting

Minimum Flow

5000