Jog Your Machine
Chapter 5
5-8
Download Jog Configuration Block (JGC)
Utilizing the same procedure outlined in chapter 3, enter your initial inject
and screw rotate jog values in Worksheet 5-B. To download this block ,
refer to the download procedure outlined in chapter 4.
Word 1 in the Dynamic Command block (DYC01) is used to enable and
disable individual jogs. Word 1 in the System Status Block (SYS01) may
also be used to monitor the QDC module’s reaction to jog commands.
Below are two quick cross-reference tables identifying the jog enable and
status bits for the inject cylinder and screw rotate:
Table 5.C
Inject Cylinder and Screw Rotate Jog Enable Bits
Control Block Word: ProĆSet 600 Address: Description:
DYC01ĆB09
B35/393
Execute Screw Rotate Jog
DYC01ĆB10
B35/394
Execute Inject Cylinder Jog Forward
DYC01ĆB11
B35/395
Execute Inject Cylinder Jog Reverse
Table 5.D
Inject Cylinder and Screw Rotate Jog Status Bits
Status Block Word: ProĆSet 600 Address: Description:
SYS01ĆB09
B35/9
Screw Rotate Jog in Progress
SYS01ĆB10
B35/10
Inject Cylinder Jog Forward in
Progress
SYS01ĆB11
B35/11
Inject Cylinder Jog Reverse in
Progress