Blank Worksheets

Appendix A

A-9

Worksheet

7-A

(continued)

First Clamp Close (FCC) Configuration Block

Control Word ProĆSet 600 Addr. Value

Description

Units

FCC05

N43:1

Minimum ERC

PercentageĆĆVelocity

Percent

8

FCC06

N43:2

Minimum ERC

PercentageĆĆPressure

Percent

8

FCC08

N43:4

Profile Watchdog Timer Preset

Time

1

FCC09

N43:5

Output #1 SetĆOutput Value during Profile

Percent Signal Output

4

FCC10

N43:6

Output #2 SetĆOutput Value during Profile

Percent Signal Output

4

FCC11

N43:7

Output #3 SetĆOutput Value during Profile

Percent Signal Output

4

FCC12

N43:8

Output #4 SetĆOutput Value during Profile

Percent Signal Output

4

FCC17

N43:13

Output #1 Acceleration Ramp Rate during Profile

Percent Signal Output per Second

5

FCC18

N43:14

Output #2 Acceleration Ramp Rate during Profile

Percent Signal Output per Second

5

FCC19

N43:15

Output #3 Acceleration Ramp Rate during Profile

Percent Signal Output per Second

5

FCC20

N43:16

Output #4 Acceleration Ramp Rate during Profile

Percent Signal Output per Second

5

FCC25

N43:21

Output #1 Deceleration Ramp Rate during Profile

Percent Signal Output per Second

5

FCC26

N43:22

Output #2 Deceleration Ramp Rate during Profile

Percent Signal Output per Second

5

FCC27

N43:23

Output #3 Deceleration Ramp Rate during Profile

Percent Signal Output per Second

5

FCC28

N43:24

Output #4 Deceleration Ramp Rate during Profile

Percent Signal Output per Second

5

FCC33

N43:29

Output #1 SetĆOutput Value at EndĆofĆProfile

Percent Signal Output

4

FCC34

N43:30

Output #2 SetĆOutput Value at EndĆofĆProfile

Percent Signal Output

4

FCC35

N43:31

Output #3 SetĆOutput Value at EndĆofĆProfile

Percent Signal Output

4

FCC36

N43:32

Output #4 SetĆOutput Value at EndĆofĆProfile

Percent Signal Output

4

FCC41

N43:37

Pressure Minimum Control Limit

Pressure

3

FCC42

N43:38

Pressure Maximum Control Limit

Pressure

3

FCC43

N43:39

Selected Pressure Valve Output for Minimum

Percent Signal Output

4

FCC44

N43:40

Selected Pressure Valve Output for Maximum

Percent Signal Output

4

FCC45

N43:41

Velocity Minimum Control Limit

Velocity along Axis

2

FCC46

N43:42

Velocity Maximum Control Limit

Velocity along Axis

2

FCC47

N43:43

Selected Velocity Valve Output for Minimum

Percent Signal Output

4

FCC48

N43:44

Selected Velocity Valve Output for Maximum

Percent Signal Output

4

FCC49

N43:45

Proportional Gain for Pressure Control

None

FCC50

N43:46

Integral Gain for Pressure Control

Inverse Time (Algorithm)

6

FCC51

N43:47

Derivative Gain for Pressure Control

Time (Algorithm)

7

Time

1

FCC52

N43:48

Proportional Gain for Velocity Control

Inverse Time (Algorithm)

6

FCC53

N43:49

Feed Forward Gain for Velocity Control

None

FCC57

N43:53

Profile High Pressure Alarm Setpoint

Pressure

3

1

Time

2

Velocity along Axis

3

Pressure

4

Percent Signal Output

00.00 to 99.99 Seconds 00.00 to 99.99 Inches per Second 0000 to 9999 PSI 00.00 to 99.99

000.0 to 999.9 Millimeters per Sec 000.0 to 999.9 Bar

5

Percent Signal Output per Second

6

Inverse Time (Algorithm)

7

Time (Algorithm)

8

Percent

0000 to 9999 00.00 to 99.99 Minutes 00.00 to 99.99 Minutes 00.00 to 99.99

00.00 to 99.99 Seconds