Installing the KF3

Chapter 2

2Ć14

230V Operation

Set the power select switch to “230V” as shown in Figure 2.19.

Figure 2.19

Power Select Switch Set for 230V Operation

ËËË

CAUTION: FOR CONTINUED

PROTECTION AGAINST RISK

OF FIRE REPLACE ONLY

WITH THE SAME TYPE

AND RATING OF FUSE.

CAUTION:

DOUBLEĆFOLD NEUTRAL

FUSES

FUSES: 0.1A 250V

TYPE 5mm X 20MM

Slide to left for

230V operation

CAUTION: The power cord supplied is approved for 115V
operation only. To guard against electrical shock or fire, you
must replace the cord with one approved for 230V AC by a
recognized agency such as Underwriters Laboratories. To
match the KF3 receptacle, the 230V power cord must be
terminated with a molded female connector (IEC 320/CEE22).

CAUTION: Before replacing fuses, unplug the module’s power
cord.

To replace fuses, insert the fuse into the fuse holder in the cap first. Then
insert the combined assembly into the fuse receptacle and tighten with a
screwdriver.

CAUTION: If you first put the fuse into the receptacle and then
attempt to tighten the cap, damage or breakage may result.

Replacing Fuses