2 - installing the kf3, Installation procedures, Interface connections – Rockwell Automation 1770-KF3 DH-485 Communication Interface User Manual User Manual

Page 9: Installing the kf3, Installation procedures interface connections

Advertising
background image

2

Chapter

2Ć1

Installing the KF3

To install the KF3, follow these steps:

1.

Define your network needs.

2.

Construct the necessary cables.

3.

Ground and terminate your network correctly.

4.

Determine the correct voltage for your application and set the KF3’s
voltage selector. Change power cord if necessary.

5.

Check the KF3’s default configuration parameters and change those
which are not suitable for your application.

Figure 2.1 shows the back panel of the KF3, including its two
communication connectors. The connector labelled RS-232 Computer
connects to the host computer via an RS-232C cable. The connector
labelled DH-485 connects to the DH-485 network.

Figure 2.1

KF3 Back Panel

ЛЛЛ

ЛЛЛ

CAUTION: FOR CONTINUED

PROTECTION AGAINST RISK

OF FIRE REPLACE ONLY

WITH THE SAME TYPE

AND RATING OF FUSE.

CAUTION:

DOUBLEĆFOLD NEUTRAL

FUSES

FUSES: 0.1A 250V

TYPE 5mm X 20MM

115V/230V

Voltage Selector
Power Switch

Fuses

AC power connector

(115V/230V)

DHĆ485 connector

links to DHĆ485

network

RSĆ232C connector

links to host computer

via RSĆ232C cable

Installation Procedures

Interface Connections

Advertising