Diagnostic status, Example of an active node table – Rockwell Automation 1770-KF3 DH-485 Communication Interface User Manual User Manual
Page 52
Advertising
Diagnostic Command Support
Appendix B
BĆ4
Example of an Active Node Table
A network consists of 5 stations, numbered 0, 3, 4, 5, and 7. The Active
Node Table would look like this:
0
1
2
3
4
5
6
7
3
FF
FF
4
5
7
FF
0
This command requests a block of status information from a DH-485
device. The reply contains the information in its DATA field. The status
information varies from device to device. The KF3’s status block is given
below.
Figure B.5
Diagnostic Status Command Format
CMD
06
STS
TNS
FNC
03
1 byte
1 byte
2 bytes
1 byte
Figure B.6
Diagnostic Status Reply Format
CMD
46
STS
TNS
DATA
1 byte
1 byte
2 bytes
24 bytes
Diagnostic Status