In

Autosense mode, the scanner has an internal object

sensor allowing you to operate the scanner in an
optional Autostand (Catalog No. 2755-NS2) for
hands-free operation.

When the scanner is placed in the Autostand it
becomes immediately active for reading any bar code
label presented to it. The scanner is triggered when a
bar code label breaks the scan beam path between the
reflective label on the stand and the scanner.

To activate Autosense mode, scan the Enable
Autostand
(NO) label. You must hold the trigger
down for two seconds after scanning the label.

NO

Enable
Autosense Mode

The scanner will respond by emitting a continuous,
low level, red beam of light.

Note: The scanner is automatically configured to use
full power (not standby power) in Autosense mode.

For details on how to set up the scanner to operate in
the optional Autostand, see Appendix C.

To deactivate Autosense mode, scan the Disable
Autostand
symbol (NN). You must hold the trigger
down for two seconds after scanning the label.

NN

Disable
Autosense Mode *

Note: Spotter Beam and Autosense Mode are
mutually exclusive parameters. Only one of these
parameters can be enabled at a time.

Autosense
Mode