Rockwell Automation 2094-BMxx-M Kinetix 6200 and Kinetix 6500 IAM and AM Power Modules Installation Instructions User Manual

Page 10

Advertising
background image

10 Kinetix 6200 and Kinetix 6500 IAM and AM Power Modules

Rockwell Automation Publication 2094-IN011D-EN-P - August 2013

3. Hang the mounting bracket from the slot on the power rail.

4. Pivot module downward and align the guide pins on the power rail with the guide pin

holes in the back of the module.

TIP

The IAM module can have two or three power rail connectors and guide pins. The AM module
can have one or two, all other modules have one.

Slots for additional axis modules,

shunt module, or slot-filler modules.

Power Rail Slot

Mounting Bracket

Power Rail

IAM or AM Power Module, IPIM,
Shunt, or Slot-filler Module
(IAM power module is shown)

Guide Pin
Holes

Power rail (side view)

in upright vertical position.

Guide Pins

Pivot module downward

and align with guide pins.

IAM or AM Power Module, IPIM,

Shunt, or Slot-filler Module, Rear View

(IAM power module is shown)

IAM or AM Power Module, IPIM,

Shunt, or Slot-filler Module, Side View

(IAM power module is shown)

Advertising