Iam/am module power wiring requirements – Rockwell Automation 2094-BMxx-M Kinetix 6200 and Kinetix 6500 IAM and AM Power Modules Installation Instructions User Manual

Page 16

Advertising
background image

16 Kinetix 6200 and Kinetix 6500 IAM and AM Power Modules

Rockwell Automation Publication 2094-IN011D-EN-P - August 2013

IAM/AM Module Power Wiring Requirements

ATTENTION: To avoid personal injury and/or equipment damage, make sure installation
complies with specifications regarding wire types, conductor sizes, branch circuit protection,
and disconnect devices. The National Electrical Code (NEC) and local codes outline provisions
for safely installing electrical equipment.

ATTENTION: To avoid personal injury and/or equipment damage, make sure motor power
connectors are used only for connection purposes. Do not use them to turn the unit on and
off.

ATTENTION: To avoid personal injury and/or equipment damage, make sure shielded power
cables are grounded to prevent potentially high voltages on the shield.

IAM/AM Module
Cat. No.

Description

Terminals

Recommended
Wire Size
mm

2

(AWG)

Strip
Length
mm (in.)

Torque Value
N•m (lb•in)

Pin

Signal

2094-BC01-M

xx-

M

2094-BC02-M02-

M

2094-BMP5-

M

2094-BM01-

M

2094-BM02-

M

Motor power

MP-4
MP-3
MP-2
MP-1

Motor power cable depends on
motor/drive combination.

6…1.5
(10…16)

10 (0.38)

0.5…0.6
(4.4…5.3)

2094-BC04-M03-

M

2094-BM03-

M

10…1.5
(8…16)

10 (0.38)

1.2…1.5
(10.6…13.2)

2094-BC07-M05-

M

2094-BM05-

M

30…2.5
(3…14)

16 (0.63)

2.4…3.0
(21.6…26.5)

2094-BC

xx-Mxx-

M

and

2094-BM

xx-

M

Brake power

BC-6
BC-5
BC-4
BC-3
BC-2
BC-1

MBRK-
MBRK+
COM
PWR
DBRK-
DBRK+

0.75 (18)

10 (0.38)

0.22…0.25
(1.9…2.2)

W
V
U

Advertising