Iam/am module power wiring requirements – Rockwell Automation 2094-BMxx-M Kinetix 6200 and Kinetix 6500 IAM and AM Power Modules Installation Instructions User Manual
Page 16
 
16 Kinetix 6200 and Kinetix 6500 IAM and AM Power Modules
Rockwell Automation Publication 2094-IN011D-EN-P - August 2013
IAM/AM Module Power Wiring Requirements
ATTENTION: To avoid personal injury and/or equipment damage, make sure installation 
complies with specifications regarding wire types, conductor sizes, branch circuit protection, 
and disconnect devices. The National Electrical Code (NEC) and local codes outline provisions 
for safely installing electrical equipment.
ATTENTION: To avoid personal injury and/or equipment damage, make sure motor power 
connectors are used only for connection purposes. Do not use them to turn the unit on and 
off.
ATTENTION: To avoid personal injury and/or equipment damage, make sure shielded power 
cables are grounded to prevent potentially high voltages on the shield.
IAM/AM Module 
Cat. No.
Description
Terminals
Recommended 
Wire Size
mm
2
(AWG)
Strip 
Length
mm (in.)
Torque Value
N•m (lb•in)
Pin
Signal
2094-BC01-M
xx-
M
2094-BC02-M02-
M
2094-BMP5-
M
2094-BM01-
M
2094-BM02-
M
Motor power
MP-4
MP-3
MP-2
MP-1
Motor power cable depends on 
motor/drive combination.
6…1.5
(10…16)
10 (0.38)
0.5…0.6
(4.4…5.3)
2094-BC04-M03-
M
2094-BM03-
M
10…1.5
(8…16)
10 (0.38)
1.2…1.5
(10.6…13.2)
2094-BC07-M05-
M
2094-BM05-
M
30…2.5
(3…14)
16 (0.63)
2.4…3.0
(21.6…26.5)
2094-BC
xx-Mxx-
M
and
2094-BM
xx-
M
Brake power
BC-6
BC-5
BC-4
BC-3
BC-2
BC-1
MBRK-
MBRK+
COM
PWR
DBRK-
DBRK+
0.75 (18)
10 (0.38)
0.22…0.25 
(1.9…2.2)
W
V
U