Determine Mounting Order

Mount the IAM, AM/IPIM, shunt, and slot-filler modules in the order (left to right) as shown.
Mount the axis modules and IPIM modules according to power utilization (highest to lowest)
from left to right starting with the highest power utilization. If power utilization is unknown,
position axis modules (highest to lowest) from left to right based on amp rating.

Power utilization is the average power (kW) consumed by a servo axis. If Motion Analyzer
software was used to size the axis, the calculated axis power required can be used for the power
utilization value. If Motion Analyzer software was not used, you can use the continuous power
value (kW) for each module to determine mounting order.

Kinetix 6200/6500 (400V-class) Axis Modules

Kinetix 6000M (400V-class) IPIM Module

Module Mounting Order Example

Attribute

2094-BMP5-M

2094-BM01-M

2094-BM02-M

2094-BM03-M

2094-BM05-M

Continuous Power Output,
nom

1.8 kW

3.9 kW

6.6 kW

13.5 kW

22.0 kW

Attribute

2094-SEPM-B24-S

Continuous Power Output, nom

15.0 kW

Highest Power Utilization

Lowest Power Utilization

Integrated Axis Module

2094-BC01-MP5-M

IPIM Module

2094-SEPM-B24-S

Axis Module

2094-BMP5-M

Axis Module

2094-BMP5-M

Axis Module

2094-BMP5-M

Axis Module

2094-BMP5-M

Shunt Module

2094-BSP2

Slot Filler Module

2094-PRF