Rockwell Automation 2094-BMxx-M Kinetix 6200 and Kinetix 6500 IAM and AM Power Modules Installation Instructions User Manual

Page 13

Advertising
background image

Kinetix 6200 and Kinetix 6500 IAM and AM Power Modules 13

Rockwell Automation Publication 2094-IN011D-EN-P - August 2013

AM Power Module Features and Indicators

IAM/AM Module Connectors

ATTENTION: To avoid damage to equipment, do not mount your Bulletin 2094 control
module to the power module when the Power-applied indicator is on. Remove all input
power from the IAM power module before mounting the control module.

Designator

Description

Connector

Module

CPD

Control input power (drive)

2-position plug/header

IAM

IPD

VAC input power (drive) and DC bus

6-position plug/header

IAM

CED

Contactor enable

2-position plug/header

IAM

MP

Motor power

4-position plug/header

IAM/AM

BC

Motor/resistive brake

6-position plug/header

IAM/AM

1

2

3

W

V
U

MBRK -

MBRK +

COM

PWR

DBRK -

DBRK +

1 2 3 4

1 2 3 4 5 6

5

4

Item

Description

1

Motor cable shield clamp

2

Motor power (MP) connector

3

Motor/resistive brake (BC) connector

4

Power-applied indicator

5

Mounting screw

AM Power Module, Top View
(2094-BMP5-M is shown)

AM Power Module, Front View

(2094-BMP5-M is shown)