Kinetix 6200 and Kinetix 6500 IAM and AM Power Modules 11

Rockwell Automation Publication 2094-IN011D-EN-P - August 2013

5. Gently push the module against the power rail connectors and into the final mounting

position.

6. Use 2.26 N•m (20 lb•in) torque to tighten the mounting screws.

7. Repeat

step 1

through

step 6

for each AM, IPIM, shunt, or slot-filler module in your

Bulletin 2094 drive system.

IMPORTANT

There are two mounting screws when mounting 2094-BC04-M03-M, and
2094-BC07-M05-M (double-wide) IAM modules, and 2094-BM03-M and
2094-BM05-M (double-wide) AM modules.

Power Rail

Bracket secured in slot.

IAM or AM Power Module, IPIM,

Shunt, or Slot-filler Module

(IAM power module is shown)

Mounting Screws

Bottom front view of

IAM module.

Bottom front view of
AM, shunt, or
slot-filler module
(AM module is shown).