Iam input connector pinouts, Iam /am motor power and brake connector pinouts – Rockwell Automation 2094-BMxx-M Kinetix 6200 and Kinetix 6500 IAM and AM Power Modules Installation Instructions User Manual

Page 14

Advertising
background image

14 Kinetix 6200 and Kinetix 6500 IAM and AM Power Modules

Rockwell Automation Publication 2094-IN011D-EN-P - August 2013

IAM Input Connector Pinouts

Control Power Connector

DC Bus and Input Power Connector

Contactor Enable Connector

IAM /AM Motor Power and Brake Connector Pinouts

Motor Power Connector

CPD Pin

Description

Signal

1

Control power VAC input

CTRL 2

2

CTRL 1

IPD Pin

Description

Signal

1

An integral, unregulated power supply, consisting of AC line input, three-phase bridge
rectifier, and filter capacitors

DC-

2

DC+

3

Chassis ground

4

Three-phase input power

L3

5

L2

6

L1

CED Pin

Description

Signal

1

Relay-driven dry contact used in the safety string for a three-phase power contactor

CONT EN-

2

CONT EN+

MP Pin

Description

Signal

4

Chassis ground

3

Three-phase motor power

W

2

V

1

U

IMPORTANT

To meet CE requirements, combined motor-power cable length for all axes on the same DC bus
must not exceed 240 m (787 ft) with 460V systems. Drive-to-motor power cables must not
exceed 90 m (295.5 ft).

Advertising