Serial Communication Parameters

Chapter 6

6–11

The scanner supports three levels of serial buffering:
Full Buffering, No Buffering, One Label Buffering.

Full Buffering

With Full Buffering (the default) selected, the scanner
will place all scanned labels into a 64 byte serial
transmit buffer if the host is unavailable to receive
data. This allows you to continue scanning even
though the previous label may not have been
transmitted yet. Scanning will continue normally
until the buffer is full, then scanning will stop.
Scanning will continue when enough space is
available for the current message.

Note: The buffer holds other message parameters, so
you must consider the total message length (including
label) to determine how many labels can be buffered.
See Chapter 7, Message Format Parameters.

No Buffering

When No Buffering is selected, scanning is stopped
until the current label is completely transmitted.

One Label Buffering

When One Label Buffering is selected, the scanner
will allow you to scan one more label in addition to
the label already in the transmit buffer.

NE

Full Buffering *

NF

No Buffering

One Label Buffering

NG

Serial
Transmit Buffer