Message Format Parameters

Chapter 7

7–10

When the scanner is triggered, the scan beam is
active until:

1. a label is decoded

2. the trigger is released

3. the scan beam timeout period has elapsed

If the No Read Message is enabled, case 2 and 3 will
cause the scanner to substitute NR (No Read) for the
bar code data in the host message.

Prefix

Scanner Identifier

Code Identifier

12345

Postamble

Suffix

Preamble

Prefix

Scanner Identifier

Code Identifier

NR

Postamble

Suffix

Preamble

No Read Message enabled

No Read Message disabled

NR substituted for bar code data in host message

Bar code data ”12345” transmitted in host message

The No Read Message is disabled as the default state.

Scan label NY to enable the No Read Message.

NY

Enable
No Read Message

Scan label NX to disable the No Read Message.

NX

Disable
No Read Message*

No Read Message