No read message – Rockwell Automation 2755-G6-D Scanner with RS-232 Option User Manual
Page 63

Message Format Parameters
Chapter 7
7–10
When the scanner is triggered, the scan beam is
active until:
1. a label is decoded
2. the trigger is released
3. the scan beam timeout period has elapsed
If the No Read Message is enabled, case 2 and 3 will
cause the scanner to substitute NR (No Read) for the
bar code data in the host message.
Prefix
Scanner Identifier
Code Identifier
12345
Postamble
Suffix
Preamble
Prefix
Scanner Identifier
Code Identifier
NR
Postamble
Suffix
Preamble
No Read Message enabled
No Read Message disabled
NR substituted for bar code data in host message
Bar code data ”12345” transmitted in host message
The No Read Message is disabled as the default state.
Scan label NY to enable the No Read Message.
NY
Enable
No Read Message
Scan label NX to disable the No Read Message.
NX
Disable
No Read Message*
No Read Message