Interface Cable Pinouts

The Catalog No. 2755-NCR1 Cable is typically used
to connect the scanner to IBM PC Compatible
computers. You may have to use an adapter if your
computer has a 9-pin port.

T

a

b

le D.1

RS232 DCE, 25-Pin, Female, D-Type Connector
Catalog No. 2755-NCR1

Pin

Signal Name

Function

2

RxD

Serial data receive input.

3

TxD

Serial data transmit output.

4

CTS

Clear-To-Send (or External Trigger)
Handshaking input line.

1

5

RTS

Request-To-Send
Handshaking output line.

7

Ground

Ground pin and reference for both output signals.

External trigger operation is controlled by applying an external signal to the
CTS input (with external triggering enabled). CTS protocol and External Trigger
Enabled are mutually exclusive parameters. See Chapter 5 for details on how