Rockwell Automation 2755-G6-D Scanner with RS-232 Option User Manual
Page 74

Symbologies
Chapter 8
8–11
Minimum Length
To set a minimum length (other than two) for
Interleaved 2 of 5, scan label PD and then two digits
(02-32) in Appendix B. The value of the number
you scan must be even. Odd numers are ignored.
PD
Minimum Length
+
(Specified by two digits 02-32)
For example, to enter a minimum length of 12, scan
the PD label, then scan codes 1 and 2 in Appendix B.
Maximum Length
To set a maximum length for Interleaved 2 of 5, scan
label PE and then two digits (02-32) in Appendix B.
The value of the number you scan must be even.
PE
Maximum Length
+
(Specified by two digits 02-32)
For example, to enter a maximum length of 12, scan
the PE label, then scan codes 1 and 2 in Appendix B.
If the minimum and maximum lengths are set
equal, only codes of that exact length are read.