Symbologies

Chapter 8

8–11

Minimum Length

To set a minimum length (other than two) for
Interleaved 2 of 5, scan label PD and then two digits
(02-32) in Appendix B. The value of the number
you scan must be even. Odd numers are ignored.

PD

Minimum Length

+

(Specified by two digits 02-32)

For example, to enter a minimum length of 12, scan
the PD label, then scan codes 1 and 2 in Appendix B.

Maximum Length

To set a maximum length for Interleaved 2 of 5, scan
label PE and then two digits (02-32) in Appendix B.
The value of the number you scan must be even.

PE

Maximum Length

+

(Specified by two digits 02-32)

For example, to enter a maximum length of 12, scan
the PE label, then scan codes 1 and 2 in Appendix B.

If the minimum and maximum lengths are set
equal, only codes of that exact length are read.