Attaching the MobileView Connection Cable

You can attach the Connection Cable on either side of the terminal for
right or left-hand operation. To relocate the cable, simply grasp the
strain relief and/or the plug and slide off of mount with a rocking
motion.

Attaching Connection Cable on Right Side

Attaching Connection Cable on Left Side

IMPORTANT

Make sure the K3, 11-pin female connector clicks
completely into S19, Main Connector when plugged in.
Ensure proper seating of K2, 8-pin RJ-45 jack into S4,
Ethernet Connector.

To avoid pinching the cable with the back cover, avoid
laying the cable on top of the T-supports.

After routing the cable, secure the back cover to the
terminal. To maintain IP54 degree protection, tighten the 6
screws to a torque of 4.42 in-lb.