Chapter

5

CE Thin Client Operating Instructions

Chapter Objectives

This chapter provides instructions on how to:

• start up or power on the MobileView terminal
• set up an auto start sequence
• configure Ethernet network settings
• save registry settings
• start terminal services
• shut down or power off the MobileView terminal
• reset the time and date

Starting Up/Powering On
the Terminal

To start up or power on the MobileView terminal:

1. Attach the MobileView Connection Cable to the Junction Box

Cable as shown on page 2-4. Tighten threaded coupling until it
is finger tight.

2. Check the MobileView terminal for a start-up screen.

If the start-up screen does not appear, check the 24V dc power
source and cable connections at the Junction Box and
MobileView terminal.