Rockwell Automation 9329 Drive Application Software Tension Control Gen. Units User Manual

Page 20

Advertising
background image

FM – Tension Control

Drive Application Software – page 20 of 52

4.4.21 J_sec

J_sec is the total inertia reflected back to the motor. For variable diameter rolls, the
inertia comp routine will calculate this value. For constant diameter rolls, the drive
calculates this value. For the PowerFlex 700S, parameter 9 is the total system inertia
reflected back to the motor in seconds. Inertia in seconds is define as the Time to
reach base motor speed at rated motor torque.
Usage – Connect to the J_sec tag or set the value of J_sec in the JSR Instruction.

4.4.22 LogicStat

This is the logic status from the tension control routine. The logic status tag is used
by other routines in the Tension Control Function Module.

Bit 00

Control On: The tension control regulator is active.

Bit 01

Tension Control: The tension control regulator is controlling tension.

Bit 02

Torque Control: The tension control regulator is controlling torque.

Bit 03

Dancer Control: The tension control regulator is controlling dancer
position.

Bit 04

Torque Follower Control: The drive is following the torque reference
from another drive.

Bit 05

Torque Trim: The tension control regulators output is summing with the
drive torque reference.

Bit 06

Speed Trim: The tension control regulator’s output is summing with
drive’s velocity reference.

Bit 07

Bit 08

PI Integral Hold High: The PI Regulator is inhibited in increasing its
output.

Bit 09

PI Integral Hold Low: The PI Regulator is inhibited form decreasing its
output.

Bit 10

Stall Tension: The Tension Control’s Reference is the stall tension
reference.

Bit 11

TrqFbJloss: The Torque feedback from the drive includes the inertia
and losses

Bit 12

Torque Memory On: The Torque Memory is enabled.

Bit 13

Bit 14

Bit 15

Bit 16

Tension Reference Off: The tension control regulator is not active

Bit 17

Dancer Reference Off: The tension control regulator is not controlling
position of a dancer.

Bit 18

Min/Max Torque: The tension control regulator is set up for Min/Max
Torque.

Bit 19

Min/Max Torque On. The tension control regulator is actively controlling
torque.

Bit 20

Regulator On: The tension control regulator is on.

Bit 21

Regulator Off: The tension control regulator is off.

Bit 22

FeedForwardOn: The tension control algorithm is feed forwarding a
torque signal.

Bit 23

TorqueFeedForwardNegage: The feed forward term is negated.

Bit 24

TorqeFeedbackNegate: The Torque feedback is negated.

Bit 25

TrimOutputNegate: The output of the tension control regulator is
negated

Bit 26

TorqueReferenceOn: The drive is following a torque follower

Bit 27 -

31

Not used


Advertising