Rockwell Automation 9329 Drive Application Software Tension Control Gen. Units User Manual

Page 33

Advertising
background image

FM – Tension Control

Drive Application Software – page 33 of 52

5.2.1.15

GearRatio – In 18

Enter a real tag that contains the gear ratio. If the gear ratio is entered directly,
make sure to enter at least one digit after the decimal point.

5.2.1.16

MtrTorqRated_EU – In 19

Enter a real application tag that contains the Rated Motor Torque. If the rated
motor torque is entered directly, make sure to enter at least one digit after the
decimal point.

5.2.1.17

LineSpeedMax_EU – In 20

Enter a real tag that contains the Maximum Line Speed value. If the maximum
line speed is entered directly, make sure to enter at least one digit after the
decimal point.

5.2.1.18

J_sec – In 21

Enter a real tag that contains the system inertia in seconds. This typically is
produced by the JCalc routine.

5.2.2 Output Parameters

5.2.2.1

TenCtrlLogicStat – Ret 1

This output verifies that the Tension Control Logic Routine has accepted the
control inputs properly and is used to control the remaining Tension Control
Function Module routines.

5.2.2.2

TrqPerTen – Ret 2

This output is used for scaling the tension values to torque.

5.2.2.3

TrqPerLineSpdSec – Ret 3

This output is the amount of torque required to accelerate the present load one
percent (1%) of maximum speed.

5.2.3 Default Tags used in Drive Application Software


Advertising