PROFIBUS DP Communications

36

Publication 2711-6.3

Validation Messages

Validation Message

Recommendation(s)

Missing ’:’ after PI / POxxx specifier.

Add colon to tag addresses.

Bad Word number. Word number range is 0 - 15.

Specify word number from 0 to 15.

Bad Bit number. Bit number range is 0 - 15.

Specify bit number from 0 to 15.

Bad character used as bit delimiter. The bit delimiter is a ’/’.

Use correct delimiter in tag addresses.

Invalid length. Bit arrays cannot cross word boundaries.

Specify different bit array in tag address.

Direction definition (write/read) must match PI/PO.

PI = DP Master Read, PO = DP Master Write

Extra characters following a valid address.

Delete extra address characters.

No bit field allowed when Tag Type is not Bit.

Tag type and data type must be compatible.

Character string is out of PI/PO boundary.

Do not exceed the data block word boundary.

This float data is out of the PI/PO boundary.

The maximum word number for a float is 14.

For PI/PO 1 to 127, WORD#0 is reserved. Word range is 1-15.

Note: Word 0 is multiplex module command or status word.

PI/PO number is missing. Define a number after the section PI or PO.

Specify a number from 0 to 127.

Bad Word number. Word number range is 1-15.

For block numbers >0 (multiplex blocks), specify a word number
from 1 to 15.

This data is out of the PI/PO boundary.

Do not exceed the data block word boundary.

Cannot be converted to current protocol format

Warning Messages

Validation Message

Recommendation(s)

The total size of the Input Modules is larger than 32 bytes.

Information message.

The total size of the Output Modules is larger than 32 bytes.

Information message.

Communication settings have never been initialized.

Indicates the default node address was not changed.

PanelBuilder Error