Rockwell Automation 2755 StrataSet Programming Software User Manual

Page 26

Advertising
background image

2–15

Configuring your Reader

Publication 2755-6.14

Output/Package Detect Type

Description

Buffer scans until package
detect cycle completes

StrataScan Readers have the ability to buffer all bar
codes as they are scanned (with Package Detect
support enabled). If this option is enabled, all
scanned bar codes are buffered during the active
sensor cycle and are not transmitted, until the
activation cycle has completed. This feature is
supported with all 3 Package Detect mode options. If
this feature is not enabled, all scanned bar codes are
transmitted as they are scanned. This option does not
apply to the special code select feature, which always
buffers incoming bar codes.

Enable host package detect
emulation

When this option is enabled, the host simulates the

Package Detect input(s) by sending an

S’ (53h)

character and an

X’ (58h) character. If dual Package

Detects is enabled, the

S’ simulates the Package

Detect input 1 and the the

X’ simulates the Package

Detect input 2. If a finite scan duration is being used,

the

S’ character starts the cycle. If scan duration > 9

seconds (reader active until the sensor goes away),

the

S’ starts the cycle and the

X’ ends the cycle.

Scan Range

This section provides depth of field options. Long depth of field
should be enabled in all StrataScan Readers. The 2 reserved options
are not currently supported and are reserved for future use.