Operation, General, Indicators – Rockwell Automation 4100 ESRS Encoder Signal Reference Simulator Installation Manual User Manual
Page 27: Controls, Line speed, When set to unidirectional, General -1 indicators -1 controls -1, Line speed -1, When set to unidirectional -1, Chapter
 
1
Publication 4100-IN505A-EN-P - October 2000
Chapter
3
Operation
General
Your ESRS is fitted with a range of indicators and controls to allow 
easy configuration and use. This chapter explains the function and 
operation of these and provides additional technical data where 
appropriate.
Indicators
There are two green LED indicators provided on the ESRS front panel: 
OK and Enable.
The OK indicator relates the status of the applied power (either +5V 
DC or +12V DC) and associated fuse. When the LED is lit, it indicates 
that power is applied and the fuse is healthy.
The Enable indicator relates the status of the Enable input. When it is 
lit, the Enable input is active and the ESRS is enabled.
Controls
The ESRS provides controls for Line Speed, Acceleration, Rounding, 
and Line Selection. 
Line Speed
The Line Speed control of the ESRS allows the user to set the desired 
line speed from the ESRS. The control is a 270 degree potentiometer 
accessible from the front panel of the ESRS. For tamper avoidance, the 
control is screwdriver operated. The function of this control is 
dependent on whether the Option Switch is set to Unidirectional or 
Bi-directional.
When Set To Unidirectional
When Unidirectional Mode is selected, zero speed occurs in the MIN 
position and maximum speed occurs in the MAX position. The 
direction of rotation in this mode is set by the Options switch.