3-8 Operation

Index Division Ratio Selection

Switch 3 and Switch 4 are used to create 4 patterns based on their
ON/OFF combinations. The patterns determine the pulse ranges, the
pulses per revolution, and the counts per revolution.

Maximum Effective Motor Speed

The Maximum Effective Motor Speed is dependent on the combined
values for Switch 3 and Switch 4. Only one of the switches numbered
5 through 10 should be in the ON position. The default setting has
Switch 5 in the ON position with switches 6 through 10 in their OFF
positions.

Table 3.D Index Division Ratio Selection

Switch Settings for
Switch 3/ Switch 4

Pulse
Range

Pulses Per
Revolution

Counts per
Revolution

OFF/OFF

2

10

1024

4096

ON/OFF

2

11

2048

8192

OFF/ON

2

12

4096

16384

ON/ON

2

13

8192

32768

TIP

Having more than one switch, in series 5 through 10,
set to the ON position results in an undefined
maximum RPM speed. No switches, in series 5
through 10, set to the ON position results in an
output speed of zero. In either case, no damage is
done to the ESRS.

Table 3.E Maximum Effective Motor Speed (RPM) Selection

Switch
Number

Switch 3 and 4 set
to: OFF/OFF

Switch 3 and 4 set
to: ON/OFF

Switch 3 and 4 set
to: OFF/ON

Switch 3 and 4 set
to: ON/ON

5

1500

750

375

187

6

3000

1500

750

375

7

6000

3000

1500

750

8

9000

4500

2250

1125

9

12000

6000

3000

1500

10

15000

7500

3750

1875

Advertising