Operation 3-7

Setting the Option Switch

You must remove the side panel of the ESRS box to gain access to the
DIP switches.

Set the DIP switches by pressing the appropriate lever to either its ON
or OFF position based on the following switch setting values.

When configuring the ESRS with the DIP switches, some of the
settings are cumulative. These setting combinations determine the
actual configuration. Make sure all of the levers are in the correct
position for the desired configuration.

Mode Selection

DIP switch levers 1 and 2 determine the operating mode of the ESRS.

Switch 1 – ON = Unidirectional; OFF = Bi-directional.

Switch 2 – ON = Unidirectional Mode - Forward;
OFF = Unidirectional Mode - Reverse.

ATTENTION

!

Removal of the side panel and setting of DIP
switches should be performed by authorized
personnel only. Proper safety precautions must be
followed to reduce the risk of damage to the unit,
other equipment, and health of personnel.

TIP

When Switch 1 is in the OFF position, for
Bi-directional Mode, Switch 2 has no effect.

Advertising