Inputs and outputs, Line speed ref out, Strobe out – Rockwell Automation 4100 ESRS Encoder Signal Reference Simulator Installation Manual User Manual

Page 29: Inputs and outputs -3, Line speed ref out -3 strobe out -3

Advertising
background image

Publication 4100-IN505A-EN-P - October 2000

Operation 3-3

EXT – This setting selects a customer supplied line speed input via the
EXT LINE SPEED IN input.

Inputs and Outputs

The following analog and digital inputs and outputs are provided.

Line Speed Ref Out

The ESRS provides an analog indication of commanded speed after
rounding and acceleration have been applied. The analog output
range is 0V > Vout > 10V.

The output produces a voltage ranging from 0 to +10 V DC as the
commanded speed varies from stationary to the selected maximum.
Within the speed range selected, the output voltage is directly
proportional to speed.

In Bi-directional Mode, this output produces +10V DC at maximum
speed for both directions of rotation. The direction of rotation is then
defined by the quadrature pulse phase via the Phase Output.

The impedance of this output is approximately 300

. Therefore to

ensure low interface errors, any device connected to this output
should have an input resistance of greater than 30k

.

Strobe Out

The Strobe Out is a TTL Digital Output providing a buffered signal to
trigger stroboscopes, oscilloscopes, and so forth.

This output provides a TTL square wave whose rising edge is
synchronized to the rising edge of the Index pulse.